Module library

Quantize Live Rec Toggle for Elektron Octatrack

Hold [REC] and tap [PLAY] to see QUANTIZE LIVE REC in a toast; tap [PLAY] again while it is up to switch it.

Module version 0.1.1-experimental. Base firmware: 1.40C.

About this module

QUANTIZE LIVE REC decides whether live-recorded trigs snap to the steps. Stock keeps it in PROJECT > SYSTEM > PERSONALIZE. This module shows it on the gesture that starts live recording and lets a second tap switch it, without leaving the page you are on.

How to use it

  1. Hold [REC] and tap [PLAY]: a toast shows LIVE REC: QUANTIZED or LIVE REC: UNQUANTIZED, the current setting, and live recording starts as on the stock OS.
  2. While the toast is still on screen (about one second), keep [REC] held and tap [PLAY] again to invert the setting; the toast reopens with the new value.
  3. Tap [PLAY] once more while it is up to switch back, or release [REC] to close the toast; the setting stays as last shown.
  4. Press [STOP] to end live recording. PROJECT > SYSTEM > PERSONALIZE > QUANTIZE LIVE REC shows and edits the same setting.

Controls

QUANTIZE LIVE REC
The stock PERSONALIZE setting. QUANTIZED is the ticked QUANTIZE LIVE REC box. The module does not change its stored value or default; it only adds the [REC] + [PLAY] gesture that shows and inverts it.

Compatibility notes

Test evidence

The image gate passes 36 checks on the native image of this module alone: the retired 0x400522ca site left as the original OS has it, both jmp detours and the unit's 196 bytes in place, then under the ColdFire port by the keys (MKII panel) the show, invert, invert-back, expiry and [REC]-release behaviour beside the original OS under the same keys, an open PERSONALIZE list redrawn by a flip, and a power cycle of the port keeping an inverted setting. On his MKI (23 October 2026) the author flashed that image from the card and reported the gesture, the PERSONALIZE redraw and a power cycle working.

Module source and documentation